Cowel vent adjustment
Moderators: Cal_Gary, T. Highway, Monkey Man, robi
Cowel vent adjustment
Does anyone know how to adjust the cowel vent so it will sit level when closed? I did not have a seal and just put one in and the vent will not close on the front .Nice and tight on the back. Are the screws that hold the vent hinge on, on oval slots or something? Thanks for any ideas.
1952 M37
M101 trailer
1942 Chevy G506
M101 trailer
1942 Chevy G506
-
- 1SG
- Posts: 1083
- Joined: Mon Oct 22, 2007 3:47 pm
- Location: West Grove, Pa
Cowl vent
If I recall when I had mine off, the bolts do sit in oval slots, so you may have some leeway for adjustment.
Where did you find the seal? I couldn't locate one so just put a polyurethane caulk in the place of the seal.
Where did you find the seal? I couldn't locate one so just put a polyurethane caulk in the place of the seal.
- hairpin151
- PFC
- Posts: 74
- Joined: Thu Mar 06, 2008 4:05 am
- Location: Sunny Southwest-AZ
Where the vent attatches to the two arms comming from the firewall, those four holes are slotted as well as the holes the where the arm comming from the lever itself is bolted to the vent cover.Hope this all makes sense as I just replaced mine. Was'nt to bad and you can adjust so it sits down nice and tight. I got my seal from John at Midwest.
JR
JR
We got our seal from John at MWM. What we found was the the hinge points had rusted solid on the control arms. You look at them and think they are solid rivets but they are actually a shoulder rivet and suppose to rotate. We removed the 4 bolts holding the control arm assembly to the cowl (also a good time to check your circuit breakers) and pulled the whole thing out for a good grinding/priming/lube. Lot easier to work on the bench then working upside down. Once you get all the pivot points working, you may find there are too many adjustments.
Alright I think I will try to loosen the 4 bolts on the ends of the vent. I noticed that the vent was bent a little across from left to right. So a little tweeking is also required. I think I would take it out but Not until I am ready to replace the wire harness as the old wires insulation just crumbles when flexed. Always more. I got the gasket as a stip of material from Vintage Power Wagons. It was long enough that I had to cut it to fit.
OH One more question I just discovered that there is a drain tube. Thats cool ! But where does it drain to? Is there a hole in the floor? or firewall? Sorry but it just doesn't rain much out here so water has not been a big deal for me
OH One more question I just discovered that there is a drain tube. Thats cool ! But where does it drain to? Is there a hole in the floor? or firewall? Sorry but it just doesn't rain much out here so water has not been a big deal for me

1952 M37
M101 trailer
1942 Chevy G506
M101 trailer
1942 Chevy G506
-
- 1SG
- Posts: 2832
- Joined: Sat Oct 20, 2007 4:35 am
- Location: Norwood, NC
- Contact:
-
- 1SG
- Posts: 1083
- Joined: Mon Oct 22, 2007 3:47 pm
- Location: West Grove, Pa
Tube....
How far is this tube supposed to extend through the firewall? Mine only goes through about 4 or 5 inches, which would allow water to drip right on the engine. I may swap this out with a longer hose and have it drain to a spot where it hits the ground.MSeriesRebuild wrote:The drain tube goes through the firewall.
Last edited by Nickathome on Thu May 08, 2008 2:26 am, edited 1 time in total.
-
- 1SG
- Posts: 2832
- Joined: Sat Oct 20, 2007 4:35 am
- Location: Norwood, NC
- Contact:
The original dumps on the rear of the engine head, good idea in my opinion to extend it so it drips on the ground. I always wondered why it was so short, no logical reason that I know of.
Charles Talbert
www.mseriesrebuild.com
www.mseriesrebuild.com
-
- 1SG
- Posts: 1083
- Joined: Mon Oct 22, 2007 3:47 pm
- Location: West Grove, Pa
hose.
Yeah it appears to be a common heater or fuel hose, so replacing it should be a simple matter.