Advice on putting filler pipe hose on?

Discuss fixes, upgrades and modifications to your M37

Moderators: Cal_Gary, T. Highway, Monkey Man, robi

Post Reply
KenInGA
CPL
CPL
Posts: 101
Joined: Sat Dec 22, 2007 4:01 pm
Location: North Georgia

Advice on putting filler pipe hose on?

Post by KenInGA »

Anyone have any tips on putting the filler pipe hose on? I'm going out to the barn to make an attempt, but I figured I might check and see if anyone has any advice on the matter...
'62 M37B1- It runs AND stops!
djester
PFC
PFC
Posts: 71
Joined: Fri Oct 19, 2007 8:24 pm
Location: Indianapolis, In

Filler Pipe Install

Post by djester »

Good question. They are a pain! I'd like to hear the answer, too.

Dave
User avatar
m-37Bruce
1SG
1SG
Posts: 2340
Joined: Fri Oct 19, 2007 8:21 pm
Location: Midlothian,VA

Stainless Steel Murray Clamps

Post by m-37Bruce »

2.5 or 3 inches I think? I replaced mine 3 or 4 years ago.
Bruce,

1953 M-37 w/ow

Retired Again

Keep Em Rollin'

VMVA
KenInGA
CPL
CPL
Posts: 101
Joined: Sat Dec 22, 2007 4:01 pm
Location: North Georgia

Post by KenInGA »

Well, I cut mine 3 inches. The space between the fuel tank pipe and the filler pipe is about 1/2". My decision: Screw it. While I have a break for 2 weeks, my dad and I will take the whole bed off. We won't even worry about the filler pipe hose until later. The bed needs to come off so we can patch it up, so we might as well go ahead and do that while we have time!
'62 M37B1- It runs AND stops!
Rick C
SSGT
SSGT
Posts: 266
Joined: Sat Oct 20, 2007 4:01 am
Location: Rhode Island

Post by Rick C »

I soaked mine in hot water. Disconnect the filler pipe from the bed and attach the hose to the tank. Work the filler pipe onto the hose and then reattach the filler pipe. I didn't have too much trouble..
Rick C
KenInGA
CPL
CPL
Posts: 101
Joined: Sat Dec 22, 2007 4:01 pm
Location: North Georgia

Post by KenInGA »

Rick, I was thinking exactly that. Until I decided that I might as well take the whole durned bed off while I have the time and gumption to do it!

Thanks guys!
'62 M37B1- It runs AND stops!
User avatar
m-37Bruce
1SG
1SG
Posts: 2340
Joined: Fri Oct 19, 2007 8:21 pm
Location: Midlothian,VA

Sorry 4 The Confusion

Post by m-37Bruce »

I was thinking diameter of the hose, not length? I did mine at the filling station, started filling it up, much to my surprise, petrol was running all over the ground,O'Riley's was right next door!
Bruce,

1953 M-37 w/ow

Retired Again

Keep Em Rollin'

VMVA
KenInGA
CPL
CPL
Posts: 101
Joined: Sat Dec 22, 2007 4:01 pm
Location: North Georgia

Post by KenInGA »

hmmm... mine is around 2" or so, I think.
'62 M37B1- It runs AND stops!
Rick C
SSGT
SSGT
Posts: 266
Joined: Sat Oct 20, 2007 4:01 am
Location: Rhode Island

Post by Rick C »

Not sure about where you live, but no one around here had fuel safe house in a large enough diameter so I had to order mine from VPW.
Rick C
User avatar
m-37Bruce
1SG
1SG
Posts: 2340
Joined: Fri Oct 19, 2007 8:21 pm
Location: Midlothian,VA

My Bad

Post by m-37Bruce »

It has been a while since I put it together. :oops:
Bruce,

1953 M-37 w/ow

Retired Again

Keep Em Rollin'

VMVA
SOTVEN
SFC
SFC
Posts: 583
Joined: Mon Oct 29, 2007 6:50 am
Location: GREECE

Post by SOTVEN »

Hello all. I got my truck from the Greek army with a rediator fose attached to the filler neck and the breather hole next to the filler neck. The hose was working fine but when I wanted to remove my tank for cleaning it was impossible to get the hose loose. It was also impossible to remove the bolts that held the cover in place from the bed side, so I cut the hoses. Unable to find fuel hose in this diameter I reinstalled radiator hose and it has been leak free 7 years now. The installation proceedure was to install both hoses to the filler neck first and then wiggle the tank with another person's help to enter the bottom of the filler hose. The breather was more flexible and went in easily. tighten all claps after that. It worked for me. Happy holidays to all. :)
LIFE IS SHORT AND ENDS UNEXPECTEDLY. MAKE EVERY MOMENT WORTH REMEMBERING.
User avatar
mike_l
SGT
SGT
Posts: 214
Joined: Sat Oct 20, 2007 5:02 am
Location: Marion, IN
Contact:

Post by mike_l »

My filler neck base and gas tank neck are both 2 1/4" diameter.
Mike
Marion, IN
1954 M37 W/OW
1953 M101
Indiana MVPA
MSeriesRebuild
1SG
1SG
Posts: 2832
Joined: Sat Oct 20, 2007 4:35 am
Location: Norwood, NC
Contact:

Post by MSeriesRebuild »

The correct diameter is 2 1/4" ID. Do not use radiator hose, it will last a short while, but will turn soft & become gummy putting residue in your tank that will cause plugging problems, etc. The correct hose is available at NAPA, it comes in 3' lengths, most stores will cut to length. Just ask for straight stick hose that is gasoline resistant. I can call my store for a part# if you need it.
Charles Talbert
www.mseriesrebuild.com
KenInGA
CPL
CPL
Posts: 101
Joined: Sat Dec 22, 2007 4:01 pm
Location: North Georgia

Post by KenInGA »

I got mine from VPW as well, nice and thick with steel wire reinforcements. I cannot remove the filler pipe cover from my bed, nor the bed floor, so the whole thing is coming off. The front of the bed can use some TLC, too. (IE cutting part off and welding part from another bed onto it)
'62 M37B1- It runs AND stops!
Post Reply